Ge Brightspeed 16
Not A Member?Sign Up
16 slice – ge parameter scan scan type helical full rotation time 0.5 sec thickness 3.75 pitch 1.375:1 speed 27.50 interval 3.75 gantry tilt scan fov large body kvp 120 ma auto ma to 440 w/ smart ma noise index 19.51 dose reduction asir/mode 40% / plus algorithm std standard reformats thick/incr. Lung 3.75 q 3.75 algorithm lung. The refurbished GE Lightspeed 16-slice CT scanner is one of our most popular and best-selling used CT Scanners. Its price for performance is among the top of 16-slice Computed Tomography machines on the market. The refurbished GE Lightspeed 16-slice scanners is available in two separate versions, the GE Lightspeed Pro 16 and the GE Lightspeed 16. 16 slice – ge parameter group 1 ( chest) group 2 ( neck) scan type helical full helical full rotation time 0.8 sec 0.8 sec thickness 3.75 2.5 pitch 1.375:1 1.375:1 speed 27.50 27.50 interval 3.75 2.5 gantry tilt scan fov large large kvp 120 120 ma auto ma to 440 w/ smart ma auto ma to 440 w/. Rating BrightSpeed Elite (16 slice), Edge (8 slice): 90kVA BrightSpeed Excel (4 slice): 75 kVA is standard rating, 90kVA is an optional rating. Page 129: Regulation GE H EALTHCARE 5141177-100, R IRECTION EVISION RIGHT PEED LITE XCEL NSTALLATION Regulation Total load regulation as measured at the PDU input terminals must not exceed 6%.
2005 GE BRIGHTSPEED 16 New tube from GE 2015 model MX200 Performix with only 33 million Mas. LOW USE tube. XTREME console. 16 slice CT including the.
GE Healthcare - BrightSpeed Series
by GE Healthcare
- Documents
- Videos
DESCRIPTION
Capable. Compact. Convenient.The BrightSpeed Series gives you full multi detector CT capabilities in three smaller systems that are as easy to select and site as they are to operate and own.
FORUMSView All (11)
Ask a New Question0Replies6 days ago | 6 days agoNGPDU Control Board Switches - SW 2 MNL HVDC we are humanitarian Doctors working in a war zone of Syria. We have a GE BrightSpeed 4 CT scanner. The device was giving us the following error. Host:tgp Proc:tgp_subsys Error:260100152 Exception Class:Abort Severity:Secondary File:sclsrService.c Line#:559 Function:System Monitoring :Xray Exposure Interlocks Scan Type: scout scan:257/1/1 Exposure Interlock Opened. The current loop from Gantry to PDU. The cause of the failure: Console Relay While checking the NGPDU Control Board Switches, we turn on the SW 2MNL HVDC by accident. I don't know how we did that, but now the gentry is not starting up. The sub system on the side of the gentry lights up . the 120 VAC, axial drive and HVDC all light up. Microsoft bi for mac os. But the display on the gentry is not turning on, nor is there any communication between the ' scanning hardware ' and the computer. Reply |
-DrSaj121 6 days ago | 6 days agoGentry not starting up Hi. We are medics working in a war zone. We don't have skilled engineers. Right now we have a problem. The gentry is not powering up. The sub system on the side of the gentry lights up . the 120 VAC, axial drive and HVDC all light up.But the display on the gentry is not turning on, nor is there any communication between the ' scanning hardware ' and the computer.Please can you help .Reply |
1Reply3 years ago | 3 years agotank oil level to what level do you fill a hemit tank? Have some tilting tube spitsReply |
SERVICE COMPANIESView All CT Scanner Companies
FEATURES
- Superb CT capabilities
- Powered by VCT Technology
- Ultra-compact size
- Lower life-cycle costs
SERIES MODELS
Ge Brightspeed Ct Scanner
Gantry (Max. Clearance) | 70 cm |
Maximum Scan Range | 140 cm |
Slices | 8 |
Type (configuration) | Multislice |
Additional Specifications |
Gantry (Max. Clearance) | 70 cm |
Maximum Scan Range | 170 cm |
Slices | 16 |
Type (configuration) | Multislice |
Additional Specifications |
Gantry (Max. Clearance) | 70 cm |
Maximum Scan Range | 140 cm |
Slices | 16 |
Type (configuration) | Multislice |
Additional Specifications |
NEWSView All
BrightSpeed Elite with ASiRA new standard in CT> GE Healthcare continues its commitment to delivering high-image quality with lowered dose with the introduction of BrightSpeed Elite with ASiR (Adaptive Statistical Iterative Reconstruction). ASiR, a new technology, delivers up to 40% reduction in radiation dose along the entire body with no compromise in image quality. With .
FDA AlertsView All
Class 2 Recall BrightSpeed Excel/Edge/Elite Select Computed TomographyFailure to properly document the CTDI in the Technical Reference or User Manual. Download
Class 2 Recall: GE BrightSpeed Excel/Edge/Elite Select / Elite CT.Ge Brightspeed 16 Slice Ct Scanner Protocols
GE has become aware of a potential set of circumstances that could cause x-ray continuation during an unexpected table stop on certain LightSpeed VCT and BrightSpeed systems. Download
Service manual of GE Brightspeed 16 Elite CT scanner
July 10, 2018 10:26
Hello friends,
I'm looking for a service manual of GE Brightspeed16 Elite CT scanner.
Anyone have pls share it.
Rgds,
Log inor RegisterI'm looking for a service manual of GE Brightspeed16 Elite CT scanner.
Anyone have pls share it.
Rgds,
to rate and post a comment
re: Service manual of GE Brightspeed 16 Elite CT scanner
July 11, 2018 10:26
Brightspeed 16 Manual
Search GE Healthcare Common documentation. Free access and great service manuals. Unlike most OEM
re: Service manual of GE Brightspeed 16 Elite CT scanner
July 11, 2018 10:26
Search GE healthcare common documentation. Great manuals unlike most OEM
re: Service manual of GE Brightspeed 16 Elite CT scanner
July 11, 2018 10:28
'http://www3.gehealthcare.com/en/support/support_documentation_library'
Check this web site
Log inor RegisterCheck this web site
to rate and post a comment
re: Service manual of GE Brightspeed 16 Elite CT scanner Speaker signal delay calculator.
Ge Brightspeed 16 Slice Manual Pdf
July 11, 2018 10:34
Good day,
You can download it from GE website.http://apps.gehealthcare.com/servlet/ClientServlet?REQ=RNEW&MODALITY=CT
You can download it from GE website.http://apps.gehealthcare.com/servlet/ClientServlet?REQ=RNEW&MODALITY=CT
re: re: Service manual of GE Brightspeed 16 Elite CT scanner
April 16, 2019 10:13
Can you please share the document.
my id [email protected]
my id [email protected]
re: Service manual of GE Brightspeed 16 Elite CT scanner
July 18, 2018 09:02
Management Review Meeting Minutes template Subject: ISO 9001 Management Review Author: Oxebridge Quality Resources Keywords: ISO 9001 Last modified by: Chris Paris Created Date: 3/15/2012 6:04:00 PM Company: OXEBRIDGE QUALITY RESOURCE Other titles: Management Review Meeting Minutes template. Title: ISO 9000 Management Review 1 ISO 9001 Management Review Meeting 2 Management Review Concept. Clause 5.6.1. Top Management shall review the organizations QMS, at planned intervals, to ensure its continuing suitability, adequacy and effectiveness. Clause 5.6.2. Management Review Agenda (Input) 1. Results of Audit; 2. Customer feedback; 3. Iso 9001 management review meeting presentation template. Jun 19, 2016 MRM - Management Review Meeting Presentation 1. Management Review Meeting ISO 9001:2008 Quality Management System November 2014 -15 Pearl Confectionery (Pvt.) Ltd Presented by: Syed Noor Mustafa Shah 2. Flow of Presentation. Results of Internal Quality Audits (IQA-1/2014-15). Comparison of results of CARs of IQA-1/2014-15 with IQA-1/2013. Nov 25, 2019 Re: MRM (Management Review Meeting) Template for ISO 9001:2015 - Help I'll tell you how I approached it. As with the previous version of the standard, the language is such that the deliverable of some of the requirements overlap, and in a review meeting you would wind up referencing the same issue multiple times.
Ge Brightspeed Table Weight Limit
mail me at [email protected]